+62-21 4585 2506 +62-21 4585 2505

Valuebond Filter Cartridge

Valuebond Filter Cartridge 1 Valuebond Filter Cartridge 5
Valuebond Filter Cartridge 2
Valuebond Filter Cartridge 3

ValueBond Depth Filter Cartridge

A Parker Filtration Product – Asia Pacific

Valuebond Filter Cartridge 6

Product Lines

The ValueBond Nominal cartridge is one of the most economical high purity filters available in Parker. Constructed with a graded density matrix design using fine Polypropylene fibers, it provides low initial pressure drop for enhanced flow and the two-layers structure gives superior service life.

Features & Benefits

  • Two-layers structure cartridge, enhanced dirt holding capacity.
  • Polyproylene construct provides broad chemical compatibility for a variety of applications.
  • Thermally bonded without the use of any binders and adhesives.
  • Materials of construction listed in FDA 21 CFR.
  • Meets the latest EC Directives for Food Contact.

Operation Conditions

  • Maximum operating forward pressure:
    • 80°C: 1.15 bar
    • 60°C: 2.05 bar
    • 20°C: 4.10 bar
  • *Recommended change out differential pressure: 2.4 bar
  • Maximum operating temperature: 80°C

* subject to operating temperature.

Applications of Product

  • Photographic Chemicals
  • DI Water
  • Plating Solutions
  • R.O. Pre-filtration
  • Membrane Pre-filtration
  • Oil field Fluids
  • Bleach
  • Potable Water
  • Chemical Processing Fluids
Valuebond Filter Cartridge 7

Product Specifications

  • Micron ratings: Available in nominal ratings of 0.5, 1, 3, 5, 10, 25, 50, 75 and100 micron
  • Material of construction: 100% melt-blown PP
  • Nominal Length: 10”, 20”, 30”, 40”, 50”, 60”
    (254mm, 508mm, 762mm, 1016mm, 1270mm, 1524mm)
  • Inner / Outer Diameter: 28mm / 63mm

The Efficiency of ValueBond Filter Cartridge

Initial Pressure Drop
Rating (μm) Aqueous Service PSI/GPM per 10” Cartridge
0.5 0.14
1 0.11
3 0.10
5 0.08
10 0.05
25 0.04
50 0.03
75 0.02
100 0.02
Dirt Holding Capacity
Rating (μm) Capacity (g/ 10”)
0.5 25
1 40
3 50
5 63
10 105
25 120
50 150
75 175
100 200
Flow Rate and Pressure Drop Formulas
Flow Rate (gpm) = Clean ΔP x Length Factor / Viscosity x Flow Factor
Clean ΔP = Flow Rate x Viscosity x Flow Factor / Length Factor
Notes:

  1. Clean ΔP ispsi differential at start.
  2. Viscosity is centistrokes. Use Conversion. Tables for other units.
  3. Flow Factor is ΔP/GPM at 1cks for 10” (or single).
  4. Length Factors convert flow or ΔP from 10” (single length) to  required cartridge length.
Flow Rate and Pressure Drop Formulas